Security On-Site
Datacenter access is strictly limited to technical staff. Electronic security systems control data center access and are accompanied by a full compliment of motion detecting security cameras which monitor the entire facility. Our Data Center facility external walls are reinforced poured concrete. We are a fully managed facility, which means we have level 3 technicians on site 24 hours per day, allowing faster resolution of issues.
Security Personnel
Trained security guards ensure security at the Facility 24*7*365. They provide onsite incidence management. They respond to any alarm generated by any security system and/or fire system. Boom barriers are installed at the building entrance to prevent access of unauthorized vehicles.
Access Control
In addition to the presence of the security guards, the entries and exits of the facility are fitted with Biometric access control devices. The main entrance is protected by a proximity access device. The facility has a Mantrap designed to ensure that no unwarranted entry / exit can be made to / from the facility. All areas are protected with Proximity card/Biometric readers, ensuring that only authorized personnel are allowed in.
Video Camera surveillance
Our facility is monitored using video cameras CCTV - the images from which are continually scanned by our Security Guards. We also maintain a 30 day digital record in the event of unprecedented mishaps.
Fire Security
Protection from fire being a critical concern; we have invested in state-of-the-art fire detection and suppression systems comprising the Kidde VESDA Detection and Sensor Network High Sensitivity Smoke Detectors (HSSD), FM200 and CO2 based gas suppression systems and cross-zoned analog addressable detector systems. This ensures early detection and suppression of fire, preventing any damage to equipment.
Unique Early fire detection design
The DC has a unique HSSD based design, which combines the early detection benefits of HSSD with zoning benefits. This VESDA system lets us pinpoint the smoke source as early as 30 minutes before any visible smoke is generated. The design also takes care of AC generated airflow to further reduce the time of detection.
High Speed fire suppression
The FM200 based fire suppression design ensures that any fire is extinguished on release of the gas. The suppression agent has been chosen such that no damage is caused to the equipment through a chemical reaction or otherwise in case of a release. FM200 (FM-200/heptafluoropropane) is an environmentally-friendly, rapid extinguishing agent which offers the most versatile clean agent suppression capabilities available for facilities that cannot afford fire-related business interruptions. Active on fire, but inert on people (non-toxic when used in accordance with NFPA Standard 2001) FM200 leaves no residue on Class A, B and C fires. FM200 systems are UL Listed and FM Approved.